In the realm of packaging and environmental monitoring, humidity indicator cards (HICs) stand out as simple yet indispensable tools. These cards provide a quick visual assessment of the relative humidity (RH) within a sealed environment, crucial for protecting sensitive products from moisture-induced damage. NINGBO INNO PHARMCHEM CO.,LTD. offers a range of HICs designed to meet various industry needs, from electronics to pharmaceuticals.

Key Features of Humidity Indicator Cards

The core functionality of an HIC lies in its chemically treated spots. These spots undergo a visible color change when exposed to specific humidity levels. The most common progression is from blue (dry) to pink (humid). Manufacturers often offer cards with multiple spots, indicating a range of RH levels. For instance, a common configuration might display 30%, 40%, and 50% RH levels. Other specialized cards may indicate levels as low as 5% or 60%, catering to specific industry requirements such as those outlined in JEDEC J-STD-033 for semiconductor handling.

Key features to consider when selecting HICs include:

  • Number of Spots: Typically 1, 3, or 6 spots, offering different levels of detail in humidity indication.
  • Humidity Range: From low levels (e.g., 5%) critical for electronics, to broader ranges for general packaging.
  • Reversibility: Most HICs are reversible, meaning the color change can revert as humidity levels decrease, allowing for repeated monitoring.
  • Cobalt Content: Cobalt-free options are available and increasingly preferred due to environmental and health regulations.
  • Card Size and Format: Available in various sizes and sometimes with adhesive backing for easy placement.

Diverse Applications of Humidity Indicator Cards

The utility of HICs extends across numerous sectors:

  • Electronics Industry: Protecting sensitive components like PCBs, integrated circuits, and optical devices from moisture damage during storage and shipping.
  • Pharmaceuticals: Ensuring the stability and efficacy of medications by monitoring humidity within packaging.
  • Military and Aerospace: Safeguarding critical equipment and components against corrosion and environmental degradation.
  • Collectibles and Archival: Preserving the condition of trading cards, documents, and artifacts susceptible to humidity damage.
  • General Packaging: Providing a simple quality control check for any product where moisture ingress is a concern.

Selecting the Right Humidity Indicator Card

Choosing the appropriate HIC involves understanding the specific needs of your product and packaging environment. Consider the sensitivity of the items being protected. For highly sensitive electronics, cards indicating lower RH levels (e.g., 5-10%) might be necessary. For less critical applications, broader ranges may suffice. Always check if the HIC complies with relevant industry standards, such as MIL-I-8835 or JEDEC J-STD-033. NINGBO INNO PHARMCHEM CO.,LTD. offers a comprehensive selection of HICs, including various spot configurations and humidity ranges, to meet diverse application requirements. Our expertise in chemical auxiliaries and packaging solutions ensures that you receive reliable tools for effective moisture control and product integrity assurance.

By carefully selecting and utilizing humidity indicator cards, businesses can significantly enhance the protection of their products, reduce spoilage, and maintain the high quality expected by consumers and regulatory bodies.

Manufacturing Facilities

NINGBO INNO PHARMCHEM CO.,LTD. was established in 2007. It is committed to the R&D, production and sales of raw materials, pharmaceutical intermediates and fine chemicals. We striving to create a high-efficiency and high-quality integrated chemical service platform to better serve domestic and foreign customers.

Professional Export Experience

to Global Customers

WHY CHOSE US?

1. 20 years of R&D, manufacturing and sales experience, serving customers in 60 countries and regions around the world;

2. Own R&D laboratory, pilot platform and large-scale production workshop, which can meet the audit requirements of global customers;

3. We can satisfy customers' perfect transition from small scale lab requirements (gram level) to commercialization requirements (hundred tons level).

FAQ

  • A: We don't have Minimum Order Quantity, exact quantity should be provided before quotation for us to calculate the exact cost.

  • A: We don't provide free samples due to lots of request and expensive international courier's cost, we can deduct the sample charge after commercial order placed.

  • A: Our payment terms: Small or sample order: T/T IN ADVANCE. Commercial order: First order should be by T/T IN ADVANCE or L/C at sight, and following orders T/T 30~90days is acceptable subject to approval of credit application.

CONTACT US
Should you need to contact us; you may call during regular business hours, Monday through Friday, 8am – 6 pm.
NINGBO INNO PHARMCHEM CO.,LTD.
Address: No.163 Ruiqing Rd.,Ningbo 315000 China
Phone: 86-574-87319282
Fax: 86-574-27912196
SEND US AN EMAIL

NAME*

EMAIL*

COMPANY

COUNTRY*

MESSAGE*

Previous: The Essential Role of Humidity Indicator Cards in Protecting Valuable Goods

Next: Cobalt-Free Humidity Indicator Cards: Meeting Regulatory Demands and Ensuring Product Safety

All Rights Reserved